General Import Options - Parasolid / PS2 / PS3 / STEP / VX Neutral / STL / SAT Updated for the current release.

 

General Import Options Form

Invoked ByFile go to Import go to Set Options

 

Use this form to perform various tasks while importing Parasolid, PS2, PS3, STEP, VX  Neutral, STL and SAT files. 2165.gif For STL imports, the part will be converted to the VX session's units.
 

  1. Complete the form as desired.

  2. Pick OK to accept the current selections as the new defaults or Reset to return all selections to their previous defaults.
     

General

 

Auto sew geometry

Closed surface volumes will be sewed (joined) at their mating edges to form a solid once they have been imported into VX. This option requires that the imported edges fall within tolerance of each other.
 

If importing directly into an existing object or one that is currently active, the default tolerance displayed in the Part Settings Form is used. If importing into a new object (created during the import), the default system tolerance (0.1mm) is used.

 

Auto activate part

The imported file will be automatically activated for editing (i.e., it will become the active part).

 

Break trim edges

Trim loops will be evaluated for tangent discontinuities and broken if required.

 

 

Default Directory Updated for the current release.

 

0441.gifThis sets the default directory for locating files to import of the specified type. Pick the folder icon to select a path from the Directory Browser. The path will be added to the Default Directory Field. The Default directory field only applies to the active session while VX is running unless it is permanently saved using the Save Settings button on the Import Form.

 

More about the Default Directory New in VX

 

All import/export translators have their own default-directory on their options form.  If the default-directory is set, then the Directory Browser will always come up in that directory.  If the default-directory is not set, then the file browser will come up in the "last visited" directory.

 

The last visited directory is not unique.  There is one last visited for all import translators and one for all export translators.  By default, the value in the Default Directory field is set to '.' which means, use the "last visited" directory.  The file icon allows you to browse for a directory which will then be the new default.  You can set the Default Directory back to "." by selecting Reset on the form.

 

 

Others Options

 

OK - Accept the current selections and make them the defaults.

Reset - Return all selections to the previous defaults.

 

 

VX NotesNotes

 

Related Topics

Return to VX CAD/CAM Index