This command allows you to open a CAM350 database. CAM350 files formats up to, and including, version 7.X are supported.
Select the File|Import|CAM350 command. The Import CAM350 dialog box appears.
Select the desired .pcb or .cam file, and click the Open button.
Notes regarding CAM350 files:
CAM350 v7.X databases can contain panelized data. If your database contains a panel, the panel itself, the one-up image, and any symbols are saved as separate .vcam files (you are prompted to select a folder to contain the files). You are then asked if you want to view the panel or the one-up image file.
CAM350 DFM errors are added as Redline data (on a separate layer).
Polygon Voids are supported, but are not recognized as standalone entities. Voids are only relative to the closed and filled polygon that contains them. If you query a polygon void (Query|Item command), the information returned is for the polygon itself. Polygon voids also cannot be modified, added, or deleted.