Automatic deactivation of operations when failure

Purpose :

The purpose is to avoid to get all invalid operations when one operation fails (if this operation is not really important).

Supported operations :

Fillet and chamfer which are classified as finishing operations. These operations create faces which are not often used to hook other elements.

Implementation :

For existing documents : in the File | Properties - General, tick the Automatic deactivation when failure option in Special update of finishing operations paragraph.

To get this behaviour for the new documents, this option is also available in the Shape rubric of the Tools | Options function.

Message :

When an operation is automatically deactivated :

 

Correction :

To remove all errors, you can :

Error message memorization :

When an operation becomes invalid, an error message is displayed in the alpha bar. This message can be displayed later using Show error message function of the contextual menu of the operation.

 