|
|
|
|---|
Topsolid online Help Index
Icon access: ![]()
Menu access: Water
Description:
Allows to create and manage cooling systems.
The management tools
for the cooling systems are not accessible by the icons bar of TopSolid/Mold.
You will find them in the menu Water
| Management.

![]()
Icon access: ![]()
Menu access: Cooling | Create pipe circuit
Description:
Allows to create a cooling circuit.
General procedure:
Choose the conception mode:
Build up the cooling system. No matter which is your selected conception mode you will have to draw the cooling system pipe by pipe. You will have to manage every time a first point P1 and them a second point P2.
Available modification(s):
You can draw the cooling system by
entering the coordinate values of the points P1
and P2. You can
also put the points at an approximate position and dimension them with
the dimensioning tools of TopSolid'Design.
![]()
Specific point(s):
The drilling from a circuit are grouped in the symbolic tree.
This group takes into account the numbering
of the cooling circuit.
Icon access: ![]()
Menu access: Water | New tank regulation
Description:
Allows to create a tank cooling system.
General procedure:
Select the target(s) to drill.
OK or MODIFY THE DIRECTION shown on screen (by default, the mold axis, directed to the shape).
The cooling system is built on construction points. You can CREATE POINTS, PROPAGATE POINTS, or existing Select points.
Select projection points. You do not have to design your points on the "entry" face of the regulation.
Adjust the cooling parameters:
Once the regulation "inserted", you can CONTINUE or create a PRIMARY CIRCUIT.
QUIT or create another circuit.
Available modification(s):
All management functions are adapted
to this kind of regulation.
To manage the offset length,
use the translation for a TANK
REGULATION.
Specific point(s):
The drilling from a circuit are grouped in the symbolic tree.
This group takes into account the numbering
of the cooling circuit.
To extend this kind of circuit, restart
the function and project the previous designed points on the correct face
of the new plate.
![]()
Think to adjust the offset
length
with a negative value to get a through all pipe.
Icon access: ![]()
Menu access: Cooling | Visualize pipe circuit
Description:
Allows to visualize the cooling system to make a visual control.
General procedure:
Select the circuit to visualizer. You can also visualize ALL.
Select the transparency mode to apply.
APPLY to visualize the cooling circuit.
RESET to start from the beginning.
Available modification(s):
You can keep
the shapes
resulting from the visualization. If you do not ask to keep the forms
the result will disappear immediately after the exit of the function.
The kept shapes are basic ones. If
you add new lines to the circuit you will have to restart the visualization
function and ask to keep the "new" shapes after you have destroyed
the "old" ones.
Icon access: ![]()
Menu access: Cooling | Pipe circuit efficiency
Description:
Allows to verify the efficiency of a cooling circuit.
It is not a rheology test considering
the physical characteristics of the material. You use a value
define by the configuration tools
of the program.
General procedure:
Select the circuit to visualizer. You can also visualize ALL.
Select the transparency mode to apply.
RESET to start from the beginning.
Icon access: ![]()
Menu access: Cooling | Test interferences
Description:
Allows to control the possible collisions between the cooling system and the mold parts.
By default, the system dynamically
controls the collisions with the plastic part while drawing a cooling
system. You can also, by managing the configuration
tools ask for this test during the creation on all of the mold parts.
The necessary calculations needed to do so can slow the general functioning
of the program.
General procedure:
Select the circuit to control. You can also control ALL.
OK.
In case of an existing collision a window will open pointing out the interfering elements
Specific point(s):
The check between cooling components
is done automatically during the components insertion.
Extend a pipe circuit
Menu access: Water | Management | Extend
Description:
Allow to extend a circuit from one element to other.
In fact cooling circuits can
only be drawn on one element at the time.
General procedure:
Select the circuit to extend. A circuit line, can be selected from the screen or choose a pipe number.
Select the extension mode to use:
Menu access: Water | Management
Description:
Usual tools displayed for a quick access.
General procedure:
You have to activate an option during the component insertion if you want to get this king of machining.

Available modification(s):
You can edit
the compoent in the symbolic tree to modify this threading.
Icon access: ![]()
Menu access: -
Description:
Allows to insert pipe plugs.

General procedure:
Select he insertion mode, link to the PLATE or manual.
SELECTION allows you to pick more than one pipe to insert your component.
With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.
In NON DYNAMIC mode, select directly the pipe for insertion.
Select the component to insert.
Available components:
|
Standard |
Code |
|
DME Inch |
BP |
|
DME Metric |
AN |
|
Fodesco |
T - KT |
|
Futaba |
- |
|
Hasco |
Z94 - Z941 - Z941/R - Z942 |
|
Hasco Inch |
- |
|
LKM |
- |
|
Locatelli |
- |
|
Meusburger |
E2074 - E2076 - E2078 |
|
Misumi |
MSWT - MSWTS |
|
Moldjis |
PT |
|
Moldman |
E32 |
|
PCS Inch |
- |
|
Pedrotti |
ETP |
|
Progressive Inch |
- |
|
Punch |
MMS - MMSTM |
|
Rabourdin |
10 - 11 - 12 |
|
Rabourdin OXA |
- |
|
Strack Norma |
Z7746 - Z7744 |
|
Totalmatrix |
- |
|
Vap |
TC |
Pipe nipple
Menu access: -
Description:
Allows to insert pipe nipples.

General procedure:
Select he insertion mode, link to the PLATE or manual.
SELECTION allows you to pick more than one pipe to insert your component.
With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.
In NON DYNAMIC mode, select directly the pipe for insertion.
Select the component to insert.
Available components:
|
Standard |
Code |
|
DME Inch |
JP |
|
DME Metric |
200 - 300 - ATN - FDN - BEP - FN - MCB - STN - FSK - FSVK - N - PCS - SST - BSS - SVK - SK - VL |
|
Fodesco |
N - LK - VN - VK |
|
Futaba |
- |
|
Hasco |
Z80 - Z807 - Z809 - Z81 - Z811 - Z812 - Z814 - Z817 - Z819 - Z82 - Z822 - Z83 - Z87 - Z878 -Z88 - Z90 - Z905 - Z91 - Z97 |
|
Hasco Inch |
- |
|
LKM |
- |
|
Locatelli |
- |
|
Meusburger |
E2044 - E2000 - E2020 - E2040 - E2046 - E2018 - E2004 - E2060 |
|
Misumi |
JTW - JTWS - JPJ - JEMM - JEFS - WCP - NPW - JEFL - LSNF - JEMF |
|
Moldjis |
|
|
Moldman |
E301 - E302 |
|
PCS Inch |
- |
|
Pedrotti |
EIR |
|
Progressive Inch |
- |
|
Punch |
|
|
Rabourdin |
104 - 106 - 114 -116 - 117 - 10 - 12 |
|
Rabourdin OXA |
- |
|
Strack Norma |
Z7713 - Z7720 - Z7724 - Z7714 - Z7727 |
|
Totalmatrix |
- |
|
Vap |
TR - AEM - BRM |
Quick nipples
Menu access: -
Description:
Allows to insert quick nipples.

General procedure:
Select he insertion mode, link to the PLATE or manual.
SELECTION allows you to pick more than one pipe to insert your component.
With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.
In NON DYNAMIC mode, select directly the pipe for insertion.
Select the component to insert.
Available components:
|
Standard |
Code |
|
DME Inch |
- |
|
DME Metric |
- |
|
Fodesco |
900 - 901 - 902 - 930 |
|
Futaba |
- |
|
Hasco |
- |
|
Hasco Inch |
- |
|
LKM |
- |
|
Locatelli |
- |
|
Meusburger |
- |
|
Misumi |
905 - 906 - 907 - 913 - 914 - 915 |
|
Moldjis |
|
|
Moldman |
- |
|
PCS Inch |
- |
|
Pedrotti |
- |
|
Progressive Inch |
- |
|
Punch |
- |
|
Rabourdin |
900 - 901 - 902 - 930 - 903 - 904 - 940 - 905 -906 -907 - 913 - 914 - 915 |
|
Rabourdin OXA |
- |
|
Strack Norma |
- |
|
Totalmatrix |
- |
|
Vap |
- |
Baffle
Menu access: -
Description:
Allows to insert baffles.
The cooling line receiving the
component has to be defined before inserting the baffle. The function
will only make the procedure for its positioning.

General procedure:
Select he insertion mode, link to the PLATE or manual.
With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.
In NON DYNAMIC mode, select directly the pipe for insertion.
Select the component to insert.
Select the cooling line to define the orientation.
Available modification(s):
It is possible to reorient the position
of the component using Modify component
.
Available components:
|
Standard |
Code |
|
DME Inch |
BB |
|
DME Metric |
BB - BBP - BBJ |
|
Fodesco |
- |
|
Futaba |
- |
|
Hasco |
Z965 - Z967 - Z968 - Z969 |
|
Hasco Inch |
- |
|
LKM |
- |
|
Locatelli |
- |
|
Meusburger |
- |
|
Misumi |
BFPT |
|
Moldjis |
|
|
Moldman |
- |
|
PCS Inch |
- |
|
Pedrotti |
- |
|
Progressive Inch |
- |
|
Punch |
- |
|
Rabourdin |
- |
|
Rabourdin OXA |
- |
|
Strack Norma |
- |
|
Totalmatrix |
- |
|
Vap |
- |
O ring
Menu access: -
Description:
Allows to insert O rings.

General procedure:
Select insertion mode:
On cooling line
SELECTION
Select the component to insert. Pay attention to the process for O rings.
You cannot insert an O ring on an
axle. To do this use components from TopSolid'Design.
Available components:
|
Standard |
Code |
|
DME Inch |
- |
|
DME Metric |
MCF |
|
Fodesco |
- |
|
Futaba |
- |
|
Hasco |
Z98 |
|
Hasco Inch |
- |
|
LKM |
- |
|
Locatelli |
- |
|
Meusburger |
E2130 |
|
Misumi |
ORG |
|
Moldjis |
P |
|
Moldman |
Z98 |
|
PCS Inch |
- |
|
Pedrotti |
- |
|
Progressive Inch |
- |
|
Punch |
OG |
|
Rabourdin |
990 - 991 -992 |
|
Rabourdin OXA |
- |
|
Strack Norma |
Z7730 |
|
Totalmatrix |
- |
|
Vap |
JT |
Icon access: -
Menu access: Water | Management
Description:
Allows to manage, move, modify a cooling system.
Icon access: -
Menu access: Water | Management | Water line plane ![]()
Description:
Allows to set current the origin of a water line.
General procedure:
Select the pipe circuit which you want its origin set current.
Icon access: -
Menu access: Water | Management
| Modify diameter ![]()
Description:
Allows to modify the diameter of one or many water pipes at the same time.
General procedure:
Choose the cooling system to modify or select the SHAPE that contains ALL the cooling system to modify.
If you choose one drilling, choose between ALL THE CIRCUIT or ONLY PIPE.
Enter the new diameter.
Icon access: -
Menu access: Water | Management | Add ![]()
Description:
Allows to add a water line between 2 existing ones.
See the TopSolid'Mold manual
for a description of this function.
Icon access: -
Menu access: Water
| Management | Suppress ![]()
Description:
Allows to suppress a water line.
IT IS ABSOLUTELY
FORBIDDEN TO DESTROY A PIPE CIRCUIT OR A WATER LINE BY OTHER MEANS THAN
THIS FUNCTION.
General procedure:
Select the water circuit to destroy.
The system will ask if DELETE CIRCUIT attached to the selected water line. Select a water line If you just want to delete that portion of the water circuit.
Specific point(s):
It is recommended to delete the components
related to the water line before launching the suppress function.
In the case of a circuit built on
a contour, the contour returns to its basic state after the suppression
of the circuit.
Icon access: -
Menu access: Water | Management | Invert ![]()
Description:
Allows to invert a water line.
General procedure:
Select the water line to invert.
Click on the red arrow to INVERT the water line.
Specific point(s):
By default the water line exits by
the P1 point during
construction.
Icon access: -
Menu access: Water | Management | Translate ![]()
Description:
Allows to move a circuit or a water line.

General procedure:
Define the translation.
Select the circuit to move.
Select between ALL CIRCUIT or ONLY PIPE options.
Select a new element to move or define a NEW TRANSFORMATION.
Specific point(s):
In tank
cooling system design, this function allows to manage the offset distance.
Icon access: -
Menu access: Water | Management | Copy
Description:
Allows to copy a complete circuit or a water line on the same or different part of there mold.

General procedure:
Select the target to receive the duplicated circuit.
Select the transformation to be applied.
Pick the circuit to duplicate. At this point you can always CHANGE TARGET, or define a NEW TRANSFORMATION.
Then select the option between ALL CIRCUIT or ONLY PIPE .
Restart again at point 3.
Specific point(s):
The copied cooling system is
"free" (dimension, position) from the initial system.
In tank
cooling system design, this function allows to copy the cooling pipes
in the opposite block with the correct management of the offset
length
regarding the part shape.
Icon access: -
Menu access: Water | Management | Duplicate
Description:
Allows to duplicate a complete circuit or a water line on the same or different part of there mold.

General procedure:
Select the target to receive the duplicated circuit.
Select the transformation to be applied.
Pick the circuit to duplicate. At this point you can always CHANGE TARGET, or define a NEW TRANSFORMATION.
Then select the option between ALL CIRCUIT or ONLY PIPE .
Restart again at point 3.
Specific point(s):
The duplicated cooling system
is "linked" (dimension, position) to the initial system.
In tank
cooling system design, this function allows to duplicate the cooling
pipes in the opposite block with the correct management of the offset length
regarding the part shape.
Topsolid online Help Index