Your Ad Here


Topsolid online Help Index

 

Icons bar: Cooling

Icon access:

Menu access: Water

Description:

Allows to create and manage cooling systems.

The management tools for the cooling systems are not accessible by the icons bar of  TopSolid/Mold. You will find them in the menu Water | Management.

 

 

Create pipe circuit

Icon access:

Menu access: Cooling | Create pipe circuit

Description:

Allows to create a cooling circuit.

General procedure:

  1. Choose the conception mode:

  1. Build up the cooling system. No matter which is your selected conception mode you will have to draw the cooling system pipe by pipe. You will have to manage every time a first point P1 and them a second point P2.

Available modification(s):

You can draw the cooling system by entering the coordinate values of the points P1 and P2. You can also put the points at an approximate position and dimension them with the dimensioning tools of TopSolid'Design.

Specific point(s):

The drilling from a circuit are grouped in the symbolic tree. This group takes into account the numbering of the cooling circuit.

 

Create tank regulation

Icon access:

Menu access: Water | New tank regulation

Description:

Allows to create a tank cooling system.

General procedure:

  1. Select the target(s) to drill.

  2. OK or MODIFY THE  DIRECTION shown on screen (by default, the mold axis, directed to the shape).

  3. The cooling system is built on construction points. You can CREATE POINTS, PROPAGATE POINTS, or existing Select points.

  4. Select projection points. You do not have to design your points on the "entry" face of the regulation.

  5. Adjust the cooling parameters:

  1. Once the regulation "inserted", you can CONTINUE or create a PRIMARY CIRCUIT.

  2. QUIT or create another circuit.

Available modification(s):

All management functions are adapted to this kind of regulation.

To manage the offset length, use the translation for a TANK REGULATION.

Specific point(s):

The drilling from a circuit are grouped in the symbolic tree. This group takes into account the numbering of the cooling circuit.

To extend this kind of circuit, restart the function and project the previous designed points on the correct face of the new plate.

Think to adjust the offset length with a negative value to get a through all pipe.

 

Visualize pipe circuit

Icon access:

Menu access: Cooling | Visualize pipe circuit

Description:

Allows to visualize the cooling system to make a visual control.

General procedure:

  1. Select the circuit to visualizer. You can also visualize ALL.

  2. Select the transparency mode to apply.

  3. Select the representation : CYLINDER or REAL.

  4. APPLY to visualize the cooling circuit.

  5. RESET to start from the beginning.

Available modification(s):

You can keep the shapes resulting from the visualization. If you do not ask to keep the forms the result will disappear immediately after the exit of the function.

The kept shapes are basic ones. If you add new lines to the circuit you will have to restart the visualization function and ask to keep the "new" shapes after you have destroyed the "old" ones.

 

Pipe circuit efficiency

Icon access:

Menu access: Cooling | Pipe circuit efficiency

Description:

Allows to verify the efficiency of a cooling circuit.

It is not a rheology test considering the physical characteristics of the material. You use a  value define by the configuration tools of the program.

General procedure:

  1. Select the circuit to visualizer. You can also visualize ALL.

  2. Select the transparency mode to apply.

  3. RESET to start from the beginning.

 

Collision test

Icon access:

Menu access: Cooling | Test interferences

Description:

Allows to control the possible collisions between the cooling system and the mold parts.

By default, the system dynamically controls the collisions with the plastic part while drawing a cooling system. You can also, by managing the configuration tools ask for this test during the creation on all of the mold parts. The necessary calculations needed to do so can slow the general functioning of the program.

General procedure:

  1. Select the circuit to control. You can also control ALL.

  2. OK.

  3. In case of an existing collision a window will open pointing out the interfering elements

Specific point(s):

The check between cooling components is done automatically during the components insertion.

 

Extend a pipe circuit

Icon access:

Menu access: Water | Management | Extend

Description:

Allow to extend a circuit from one element to other.

In fact cooling circuits can only be drawn on one element at the time.

General procedure:

  1. Select the circuit to extend. A circuit line, can be selected from the screen or choose a pipe number.

  2. Select the extension mode to use:

 

Management tools

Icon access: / / /

Menu access: Water | Management

Description:

Usual tools displayed for a quick access.

 

Management of conical thread

General procedure:

  1. You have to activate an option during the component insertion if you want to get this king of machining.

Available modification(s):

You can edit the compoent in the symbolic tree to modify this threading.

 

Pipe plugs

Icon access:

Menu access: -

Description:

Allows to insert pipe plugs.

General procedure:

  1. Select he insertion mode, link to the PLATE or manual.

  2. SELECTION allows you to pick more than one pipe to insert your component.

  3. With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.

  4. In NON DYNAMIC mode, select directly the pipe for insertion.

  5. Select the component to insert.

Available components:

Standard

Code

DME Inch

BP

DME Metric

AN

Fodesco

T - KT

Futaba

-

Hasco

Z94 - Z941 - Z941/R - Z942

Hasco Inch

-

LKM

-

Locatelli

-

Meusburger

E2074 - E2076 - E2078

Misumi

MSWT - MSWTS

Moldjis

PT

Moldman

E32

PCS Inch

-

Pedrotti

ETP

Progressive Inch

-

Punch

MMS - MMSTM

Rabourdin

10 - 11 - 12

Rabourdin OXA

-

Strack Norma

Z7746 - Z7744

Totalmatrix

-

Vap

TC

 

Pipe nipple

Icon access:

Menu access: -

Description:

Allows to insert pipe nipples.

General procedure:

  1. Select he insertion mode, link to the PLATE or manual.

  2. SELECTION allows you to pick more than one pipe to insert your component.

  3. With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.

  4. In NON DYNAMIC mode, select directly the pipe for insertion.

  5. Select the component to insert.

Available components:

Standard

Code

DME Inch

JP

DME Metric

200 - 300 - ATN - FDN - BEP - FN - MCB - STN - FSK - FSVK - N - PCS - SST - BSS - SVK - SK - VL

Fodesco

N - LK - VN - VK

Futaba

-

Hasco

Z80 - Z807 - Z809 - Z81 - Z811 - Z812 - Z814 - Z817 - Z819 - Z82 - Z822 - Z83 - Z87 - Z878 -Z88 - Z90 - Z905 - Z91 - Z97

Hasco Inch

-

LKM

-

Locatelli

-

Meusburger

E2044 - E2000 - E2020 - E2040 - E2046 - E2018 - E2004 - E2060

Misumi

JTW - JTWS - JPJ - JEMM - JEFS - WCP - NPW - JEFL - LSNF - JEMF

Moldjis

 

Moldman

E301 - E302

PCS Inch

-

Pedrotti

EIR

Progressive Inch

-

Punch

 

Rabourdin

104 - 106 - 114 -116 - 117 - 10 - 12

Rabourdin OXA

-

Strack Norma

Z7713 - Z7720 - Z7724 - Z7714 - Z7727

Totalmatrix

-

Vap

TR - AEM - BRM

 

Quick nipples

 

Icon access:

Menu access: -

Description:

Allows to insert quick nipples.

General procedure:

  1. Select he insertion mode, link to the PLATE or manual.

  2. SELECTION allows you to pick more than one pipe to insert your component.

  3. With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.

  4. In NON DYNAMIC mode, select directly the pipe for insertion.

  5. Select the component to insert.

Available components:

Standard

Code

DME Inch

-

DME Metric

-

Fodesco

900 - 901 - 902 - 930

Futaba

-

Hasco

-

Hasco Inch

-

LKM

-

Locatelli

-

Meusburger

-

Misumi

905 - 906 - 907 - 913 - 914 - 915

Moldjis

 

Moldman

-

PCS Inch

-

Pedrotti

-

Progressive Inch

-

Punch

-

Rabourdin

900 - 901 - 902 - 930 - 903 - 904 - 940 - 905 -906 -907 - 913 - 914 - 915

Rabourdin OXA

-

Strack Norma

-

Totalmatrix

-

Vap

-

 

Baffle

Icon access:

Menu access: -

Description:

Allows to insert baffles.

The cooling line receiving the component has to be defined before inserting the baffle. The function will only make the procedure for its positioning.

General procedure:

  1. Select he insertion mode, link to the PLATE or manual.

  2. With the PLATE positioning, you can add your component in DYNAMIC on a face, or select A cooling pipe.

  3. In NON DYNAMIC mode, select directly the pipe for insertion.

  4. Select the component to insert.

  5. Select the cooling line to define the orientation.

Available modification(s):

It is possible to reorient the position of the component using Modify component .

Available components:

Standard

Code

DME Inch

BB

DME Metric

BB - BBP - BBJ

Fodesco

-

Futaba

-

Hasco

Z965 - Z967 - Z968 - Z969

Hasco Inch

-

LKM

-

Locatelli

-

Meusburger

-

Misumi

BFPT

Moldjis

 

Moldman

-

PCS Inch

-

Pedrotti

-

Progressive Inch

-

Punch

-

Rabourdin

-

Rabourdin OXA

-

Strack Norma

-

Totalmatrix

-

Vap

-

 

O ring

Icon access:

Menu access: -

Description:

Allows to insert O rings.

General procedure:

  1. Select insertion mode:

  1. Select the component to insert. Pay attention to the process for O rings.

You cannot insert an O ring on an axle. To do this use components from TopSolid'Design.

Available components:

Standard

Code

DME Inch

-

DME Metric

MCF

Fodesco

-

Futaba

-

Hasco

Z98

Hasco Inch

-

LKM

-

Locatelli

-

Meusburger

E2130

Misumi

ORG

Moldjis

P

Moldman

Z98

PCS Inch

-

Pedrotti

-

Progressive Inch

-

Punch

OG

Rabourdin

990 - 991 -992

Rabourdin OXA

-

Strack Norma

Z7730

Totalmatrix

-

Vap

JT

 

Management

Icon access: -

Menu access: Water | Management

Description:

Allows to manage, move, modify a cooling system.

 

Management - Water line plane

Icon access: -

Menu access: Water | Management | Water line plane

Description:

Allows to set current the origin of a water line.

General procedure:

  1. Select the pipe circuit which you want its origin set current.

 

Management - Ø modification

Icon access: -

Menu access: Water | Management | Modify diameter

Description:

Allows to modify the diameter of one or many water pipes at the same time.

General procedure:

  1. Choose the cooling system to modify or select the SHAPE that contains ALL the cooling system to modify.

  2. If you choose one drilling, choose between ALL THE CIRCUIT or ONLY PIPE.

  3. Enter the new diameter.

 

Management - Add

Icon access: -

Menu access: Water | Management | Add

Description:

Allows to add a water line between 2 existing ones.

See the TopSolid'Mold manual for a description of this function.

 

 

Management - Suppress

Icon access: -

Menu access:  Water | Management | Suppress

Description:

Allows to suppress a water line.

 

IT IS ABSOLUTELY FORBIDDEN TO DESTROY A PIPE CIRCUIT OR A WATER LINE BY OTHER MEANS THAN THIS FUNCTION.

 

 

 

General procedure:

  1. Select the water circuit to destroy.

  2. The system will ask if  DELETE CIRCUIT attached to the selected water line. Select a water line If you just want to delete that portion of the water circuit.

Specific point(s):

It is recommended to delete the components related to the water line before launching the suppress function.

In the case of a circuit built on a contour, the contour returns to its basic state after the suppression of the circuit.

 

Management - Invert

Icon access: -

Menu access: Water | Management | Invert

Description:

Allows to invert a water line.

General procedure:

  1. Select the water line to invert.

  2. Click on the red arrow to INVERT the water line.

Specific point(s):

By default the water line exits by the P1 point during construction.

 

Management - Translate

Icon access: -

Menu access: Water | Management | Translate

Description:

Allows to move a circuit or a water line.

General procedure:

  1. Define the translation.

  2. Select the circuit to move.

  3. Select between ALL CIRCUIT or  ONLY PIPE options.

  4. Select a new element to move or define a NEW TRANSFORMATION.

Specific point(s):

In tank cooling system design, this function allows to manage the offset distance.

 

Management - Copy

Icon access: -

Menu access: Water | Management | Copy

Description:

Allows to copy a complete circuit or a water line on the same or different part of there mold.

General procedure:

  1. Select the target to receive the duplicated circuit.

  2. Select the transformation to be applied.

  3. Pick the circuit to duplicate. At this point you can always CHANGE TARGET, or define a NEW TRANSFORMATION.

  4. Then select the option between ALL CIRCUIT or  ONLY PIPE .

  5. Restart again at point 3.

Specific point(s):

The copied cooling system is "free" (dimension, position) from the initial system.

In tank cooling system design, this function allows to copy the cooling pipes in the opposite block with the correct management of the offset length regarding the part shape.

 

Management - Duplicate

Icon access: -

Menu access: Water | Management | Duplicate

Description:

Allows to duplicate a complete circuit or a water line on the same or different part of there mold.

General procedure:

  1. Select the target to receive the duplicated circuit.

  2. Select the transformation to be applied.

  3. Pick the circuit to duplicate. At this point you can always CHANGE TARGET, or define a NEW TRANSFORMATION.

  4. Then select the option between ALL CIRCUIT or  ONLY PIPE .

  5. Restart again at point 3.

Specific point(s):

The duplicated cooling system is "linked" (dimension, position) to the initial system.

In tank cooling system design, this function allows to duplicate the cooling pipes in the opposite block with the correct management of the offset length regarding the part shape.