Sensor setting
These parameters define the distances of lead in/out for the search for the point of measure, with feed rate mode.
These four parameters correspond with order SNSET in the DMIS file.

Approach
It's the distance (A) . This distance is done with feed rate.
It's the distance from which the sensor begins the search for the point.
This distance applies with regard to the theoretical point of the sensor.
The DMIS output is : SNSET/APPRCH,2.750
Retraction
It's the distance (R) . This distance is done with feed rate.
It's the lead out distance used at the end of the operation.
This distance applies with regard to the theoretical point of the sensor.
The DMIS output is : SNSET/RETRCT,2.750
Search
It's the distance (B) . This distance is done with feed rate.
It's the search distance for the real point.
The DMIS output is : SNSET/SEARCH,10.000
Depth
It's the distance (P) . This distance is done with feed rate.
It's used ONLY for the cylinder and circle.
The DMIS output is : SNSET/DEPTH,2.600