(Software Cycle)
CYCLE/BORE,z,f,IPM IPR MMPR MMPM,c[,LOCK,i]
Advance at rapid rate to clearance c.
Advance at feedrate f to depth z.
Output spindle stop M code with dwell.
Retract at rapid rate to clearance c.
Output original spindle direction M code.
LOCK,i Specifies the dwell time for spindle stop. Initially a value of 2 seconds is assumed.
Example:
Input:
$$ Z DEPTH=1.0,FEED=7.5,IPM CLEARANCE=.1
CYCLE/BORE,1.0,7.5,IPM,.1
GOTO/0,0