CLEARP (M)

Your Ad Here




 

CLEARP/XYPLAN,d-OFF

XYPLAN,d This statement establishes a clearance plane parallel to the XY plane at a distance d. Subsequent RETRCT statements will retrace the tool tip at rapid rate to this plane.

OFF This statement cancels a previously-established clearance plane. Subsequent RETRCT statements will retract the spindle to the Z axis home point, disregarding the tool length. This is the default condition assumed.

Example:

Input:

 

CLEARP/XYPLAN,5

GOTO/3,3,0

GOTO/6,6,0

RETRCT

GOTO/10,10

CLEARP/OFF

RETRCT

 

Machine Data File Output:

 

N0004G01X003Y003Z0F001$

N0005X006Y006$

N0006G00Z0005F0$

N0007G01X01Y01Z0F001$

N0008G00Z03F0$

 

SPSTCMND.chm