ARCMOV/CCLW-CLW,xe,ye,zw,a
This command is the arc motion command and follows all ARCDAT commands.
CCLW-CLW Specifies the direction of the arc move.
xe,ye,zw Specifies the end point of the arc move. The start point is assumed to be the prior point.
a Specifies the total angle in degrees, used only when the arc move is greater than 360 degrees.
Example:
Input:
GOTO/0,5,0
ARCDAT/0,0,0,0,0,1,5
ARCMOV/CLW,5,0,0,90
GOTO/5,10,0
Machine Data File Output:
N0006G01X0Y-00500Z0F01$
N0007G02X00500Y0Z0I0500J0K0$
N0008G01Y0010000F10$
SPSTCMND.chm