Setting Initial Conditions and Reference Values

The direction and magnitude of the gravity vector and the reference density for the simulation are set via the Reference Values node. We will start with the acceleration force in the negative y-direction.


The fluid region will be initialized to a temperature of 293 K.


This completes the setup for the fluid continuum. The solid continuum can now be defined.

The solid region will be initialized to a temperature of 343 K, which will be close to its final expected temperature.