Training Guide > Simple Flow Tutorials > Mesh Comparison Tutorial > Hexahedral Mesh > Visualizing the Results
Visualizing the Results
- Activate the Vector Scene 1 display to view the velocity vector field:

- Click on the tab for the Scalar Scene 1 display to see the y+ distribution along the walls.

The maximum y+ value is 6.9292, located at the top of the obstruction. This is quite large but for the vast majority of the flow regime the y+ values are below 3.0, the maximum value considered acceptable for a rigorous examination of wall data.
The next step is Examining Plots.
Return to CD-adapco STAR-CCM+ Index