Training Guide > Meshing Tutorials > Control Valve Meshing Tutorial > Polyhedral Meshing Example > Setting the Global Mesh Reference Values
Setting the Global Mesh Reference Values
To view the global reference values required for the selected meshing models, open the Reference Values node. The following mesh inputs will be listed:
The following parameters will be used for this meshing tutorial:
|
Reference Node Name
|
Property Name
|
Value
|
|
Base Size
|
Value
|
0.06 m
|
|
Number of Prism Layers
|
Number of Prism Layers
|
2 (default)
|
|
Prism Layer Stretching
|
Prism Layer Stretching
|
1.5 (default)
|
|
Prism Layer Thickness>Relative Size
|
Percentage of Base
|
4.0
|
|
Surface Curvature
|
# Pts/circle
|
36 (default)
|
|
Surface Growth Rate
|
Surface Growth Rate
|
1.3 (default)
|
|
Surface Proximity
|
Search Floor
|
0.0 (default)
|
|
Surface Proximity
|
# Points in a gap
|
2.0 (default)
|
|
Surface Size>Relative Minimum Size
|
Percentage of Base
|
4.0
|
|
Surface Size>Relative Target Size
|
Percentage of Base
|
8.0
|
|
Tet/Poly Density
|
Growth Factor
|
1.0 (default)
|
|
Tet/Poly Density
|
Density
|
1.0 (default)
|
The base size for this example is based on the size of the diameter of the inlet and all other relative meshing values are scaled from this. We could have used absolute sizes instead. To measure any part of the geometry, you can use the Measure distance between two points
toolbar button and click on any two points on the surface. The distance between the points will be reported in the output window in meters.
To set the reference value parameters, click on the relevant node and enter the above values in the Properties window. For example, to set the base value, do the following:
- Click on the Reference Values>Base Size node.
- In the Properties window, set Value to
0.06 m.

- Repeat this for the other nodes in the list using the values supplied in the table.
Return to CD-adapco STAR-CCM+ Index