Training Guide > Meshing Tutorials > Control Valve Meshing Tutorial > Polyhedral Meshing Example > Setting the Global Mesh Reference Values

Your Ad Here




Setting the Global Mesh Reference Values

To view the global reference values required for the selected meshing models, open the Reference Values node. The following mesh inputs will be listed:

The following parameters will be used for this meshing tutorial:

Reference Node Name
Property Name
Value

Base Size

Value

0.06 m

Number of Prism Layers

Number of Prism Layers

2 (default)

Prism Layer Stretching

Prism Layer Stretching

1.5 (default)

Prism Layer Thickness>Relative Size

Percentage of Base

4.0

Surface Curvature

# Pts/circle

36 (default)

Surface Growth Rate

Surface Growth Rate

1.3 (default)

Surface Proximity

Search Floor

0.0 (default)

Surface Proximity

# Points in a gap

2.0 (default)

Surface Size>Relative Minimum Size

Percentage of Base

4.0

Surface Size>Relative Target Size

Percentage of Base

8.0

Tet/Poly Density

Growth Factor

1.0 (default)

Tet/Poly Density

Density

1.0 (default)

The base size for this example is based on the size of the diameter of the inlet and all other relative meshing values are scaled from this. We could have used absolute sizes instead. To measure any part of the geometry, you can use the Measure distance between two points toolbar button and click on any two points on the surface. The distance between the points will be reported in the output window in meters.

To set the reference value parameters, click on the relevant node and enter the above values in the Properties window. For example, to set the base value, do the following:

Return to CD-adapco STAR-CCM+ Index