www.kxcad.net Home > ProCAD Index > ProCAD 2D DESIGNER 2007

|
In this field... |
Enter/Do this... |
|
Text Style Name |
The text style that will be used by default for all AutoORTHO text, such as Equipment Tags. If the text style does not exist in the drawing template, the layer will be created based on the Text Font information provided. |
|
Text Font |
The font type, style, and size that will be associated
with the text style name. To change these properties, highlight
the field, and click the This will open up the Select Font dialog box.
|
|
Text Height |
The height of all text placed by AutoORTHO routines with the exception of Equipment Tags and dimensioning text. This height will be multiplied by the drawing scale factor. |
|
Equipment Tag Text Height |
The height of the text that will appear when the Equipment Tag routine is used. This height will be multiplied by the drawing scale factor. |
|
Revision Cloud Line Thickness |
The width of the polyline created when using the Revision Cloud function. This width will be multiplied by the drawing scale factor. |
|
Straight Flange Distance for Vessel Heads |
The length of the strange flange distance on vessel heads.
|
|
Pipe Insulation Symbol Length |
The length of the insulation symbol that is inserted when the Pipe Insulation routine is used.
|
|
Number Pipe Diameters for Pipebend Straight Ends |
When a pipe bend is placed, the dialog box will automatically use this value as the # Straight End Pipe Diameters value. For a 4” NPS, a value of 2 for this parameter will result in straight ends that are 8” in length.
|
|
Maximum Number of Characters in Balloon Before Breaking |
If the number of characters in the balloon exceeds this value, the balloon sides will automatically break to accommodate the width of the text.
This applies only to Instrument balloons. |
|
Weld Gap |
AutoORTHO will add half of a weld distance to each end of a welded component to account for the weld gap. |
|
Double Line Drafting Start Size |
When the Pipe Double / Single Line Drafting line toggle is on, double lined drafting will start at the size defined here. |
|
Pipe Double/Single Line Drafting |
When Double Line is selected, all piping and fittings will be drawn in double line drafting mode. When Single Line is selected, double lined drafting will start at the size defined in the Double Line Drafting Start Size setting. |
|
Drawing Template |
This is the AutoCAD template that will be used for each new AutoORTHO drawing. Customized templates may be used to include specific layers, dimension styles or text styles into each drawing. The template must be located in the template path that is defined on the File Locations Dialog Box. |
|
|
Click to apply the changes. |
|
|
Click to access the Help dialog box. |