Select the correct isoplane setting when inserting re-pads.
1. From the Miscellaneous Fittings
tab, select Re-Pad.
![]()
A message box appears, displaying the current pipe size.
2. Click OK.
The Select Branch Pipe Size dialog box appears.

3. From the scroll list, select the appropriate branch size.
4. Click OK.
5. In the drawing, click to select the main/branch intersection point.
6. Click to select the direction of the main pipe.
7. Click to select the direction of the branch pipe.
The Reinforcing Pad dialog box appears.

8. In the Diameter box, type the diameter value.
9. Click OK.
The re-pad appears in the drawing.