If your ISOGEN drawing attempt is successful, a return value of "0" appears in the AutoCAD command line. If the attempt is not successful, one of these error values will appear. In addition to these error messages, you can view a message file created when ISOGEN attempts to create the drawing. The message files are always located in the Project folder/ISOGEN/selected ISO style folder.
Important: Error codes 9, 13, and 1010 occur when ISOGEN cannot write to the file folder. A common cause of this is server path naming. It is critical that no spaces exist in server path names related to ISOGEN.
These error messages are reprinted from the Alias Ltd. documentation.
|
This value... |
Means... |
|
0 |
Iso created successfully |
|
1 |
ISOGEN cannot find the directory specified |
|
2 |
Invalid style for this project. The specified style cannot be found under the specified project. |
|
3 |
Specified project not found. |
|
4 |
IDFGEN handshake failed. The handshake passed to the idfdll.dll has not been verified. Note that a number of other "unexpected" failures have been found to generate this error. |
|
5 |
Could not access the specified PCF in TEMFILES. |
|
6 |
ISOGEN DLL failed to establish current directory. |
|
7 |
ISOGEN DLL failed to change directory. |
|
8 |
The handshake passed to the pisodll.dll has not been verified. |
|
9 |
ISOGEN failed to produce a valid drawing. View message file for details as there are many possible causes. |
|
10 |
IDFGEN DLL failed to restore working directory. |
|
11 |
IDFGEN DLL failed to establish current directory. |
|
12 |
IDFGEN DLL failed to change directory. |
|
13 |
IDFGEN did not complete successfully. View message file for details. One common cause is that the components in the PCF do not form a connected system. |
|
14 |
IDFGEN DLL failed to restore working directory. |
|
15 |
IDFGEN could not delete IPISOGEN\PROGRAMS\FOR036.DAT from a previous run. |
|
16 |
IDFGEN was unable to create ISOGEN.IDX file. Error opening ISOGEN.idx. Error closing ISOGEN.idx. |
|
17 |
IDFGEN was unable to copy ISOGEN.FLS to the PROGRAMS directory: error allocating memory to store a line |
|
18 |
|
|
19 |
ISOGEN handshake failed. The handshake passed to the pISOGEN.dll has not been verified. |
|
20 |
Unknown error in ISOGEN. An unexpected path through the program has occurred. |
|
21 |
PISOSGEN DLL could not find Current Working Directory. The current directory cannot be identified. |
|
22 |
PISOGEN DLL could not change directory to |PISOGEN\PROGRAMS |
|
23 |
ISOGEN failed to write banner to message file. Probably can’t find message file path: error opening ISOGEN.fls |
|
24 |
PISOGEN DLL has been unable to restore current working directory. |
|
25 |
Error opening i-gen.fls for reading |
|
26 |
Problem with the specified isometric root directory. |
|
27 |
Problem setting the current isometric root directory. |
|
28 |
Invalid file extension. |
|
29 |
Not applicable when running ISOGEN. |
|
30 |
Warning occurred creating a POD (intermediate) file. |
|
31 |
Error occurred creating a POD (intermediate) file. |
|
41 |
Cannot get path to system temp directory. |
|
42 |
System temp directory does not exist. |
|
43 |
Unable to set bore units to those specified in the input file. |
|
44 |
Unable to perform macro substitution in style ISOGEN.FLS |
|
45 |
Unable to restore original style ISOGEN.FLS |
|
50 |
Project disk is full - unable to create new output files. |
|
51 |
Fine containing temp directory is full - unable to process files. |
|
1000 |
Expected files missing in Style - e.g. no FLS, no options file |
|
1001 |
Requested units combination in inconsistent - probably means a combination of metric bore and imperial coordinates. |
|
1002 |
Invalid drawing format requested. |
|
1003 |
Problem deleting an ISOGEN message file. |
|
1004 |
Line in the options file has invalid format. |
|
1005 |
Too many switches in the options file. |
|
1006 |
Too few switches in the options file. |
|
1007 |
MicroStation design file output requested but MS_EXE environment variable is not defined |
|
1008 |
MicroStation design file output requested but MicroStation not installed |
|
1009 |
MS_EXE environment variable does not end with a \ |
|
1010 |
ISOGEN.FLS missing in Style |
|
1011 |
Options file specified in ISOGEN.FLS is missing |
|
2001 |
Inconsistent units combination (imperial coordinates and metric bores) |
|
2022 |
IDFGEN has detected disconnected pipeline. Drawings have still been created that will indicate the cause of the disconnection. |