Drawing Messages



Your Ad Here

If your ISOGEN drawing attempt is successful, a return value of "0" appears in the AutoCAD command line. If the attempt is not successful, one of these error values will appear. In addition to these error messages, you can view a message file created when ISOGEN attempts to create the drawing. The message files are always located in the Project folder/ISOGEN/selected ISO style folder.

Important: Error codes 9, 13, and 1010 occur when ISOGEN cannot write to the file folder. A common cause of this is server path naming. It is critical that no spaces exist in server path names related to ISOGEN.

These error messages are reprinted from the Alias Ltd. documentation.

This value...

Means...

0

Iso created successfully

1

ISOGEN cannot find the directory specified

2

Invalid style for this project. The specified style cannot be found under the specified project.

3

Specified project not found.

4

IDFGEN handshake failed. The handshake passed to the idfdll.dll has not been verified. Note that a number of other "unexpected" failures have been found to generate this error.

5

Could not access the specified PCF in TEMFILES.

6

ISOGEN DLL failed to establish current directory.

7

ISOGEN DLL failed to change directory.

8

The handshake passed to the pisodll.dll has not been verified.

9

ISOGEN failed to produce a valid drawing. View message file for details as there are many possible causes.

10

IDFGEN DLL failed to restore working directory.

11

IDFGEN DLL failed to establish current directory.

12

IDFGEN DLL failed to change directory.

13

IDFGEN did not complete successfully. View message file for details. One common cause is that the components in the PCF do not form a connected system.

14

IDFGEN DLL failed to restore working directory.

15

IDFGEN could not delete IPISOGEN\PROGRAMS\FOR036.DAT from a previous run.

16

IDFGEN was unable to create ISOGEN.IDX file. Error opening ISOGEN.idx. Error closing ISOGEN.idx.

17

IDFGEN was unable to copy ISOGEN.FLS to the PROGRAMS directory:

 error allocating memory to store a line
 zero line length encountered
 error opening source ISOGEN.fls (in specified project\isotype)
 error opening target ISOGEN.fls (in pISOGEN\programs)
 error closing source ISOGEN.fls (in specified project\isotype)
 error closing target ISOGEN.fls (in pISOGEN\programs)

18

 

19

ISOGEN handshake failed. The handshake passed to the pISOGEN.dll has not been verified.

20

Unknown error in ISOGEN. An unexpected path through the program has occurred.

21

PISOSGEN DLL could not find Current Working Directory. The current directory cannot be identified.

22

PISOGEN DLL could not change directory to |PISOGEN\PROGRAMS

23

ISOGEN failed to write banner to message file. Probably can’t find message file path:

 error opening ISOGEN.fls
 unable to find MESSAGE line in ISOGEN.fls
 error closing ISOGEN.fls
 error opening message file
 error closing message file

24

PISOGEN DLL has been unable to restore current working directory.

25

Error opening i-gen.fls for reading
 Error opening i-gen.fls for writing
 Error opening options file specified in i-gen.fls
 Error closing options file specified in i-gen.fls
 Error opening i-genopl for writing
 Error closing i-gen.opl
 Error closing i-gen.fls
 Error closing ISOGEN.fls

26

Problem with the specified isometric root directory.

27

Problem setting the current isometric root directory.

28

Invalid file extension.

29

Not applicable when running ISOGEN.

30

Warning occurred creating a POD (intermediate) file.

31

Error occurred creating a POD (intermediate) file.

41

Cannot get path to system temp directory.

42

System temp directory does not exist.

43

Unable to set bore units to those specified in the input file.

44

Unable to perform macro substitution in style ISOGEN.FLS

45

Unable to restore original style ISOGEN.FLS

50

Project disk is full - unable to create new output files.

51

Fine containing temp directory is full - unable to process files.

1000

Expected files missing in Style - e.g. no FLS, no options file

1001

Requested units combination in inconsistent - probably means a combination of metric bore and imperial coordinates.

1002

Invalid drawing format requested.

1003

Problem deleting an ISOGEN message file.

1004

Line in the options file has invalid format.

1005

Too many switches in the options file.

1006

Too few switches in the options file.

1007

MicroStation design file output requested but MS_EXE environment variable is not defined

1008

MicroStation design file output requested but MicroStation not installed

1009

MS_EXE environment variable does not end with a \

1010

ISOGEN.FLS missing in Style

1011

Options file specified in ISOGEN.FLS is missing

2001

Inconsistent units combination (imperial coordinates and metric bores)

2022

IDFGEN has detected disconnected pipeline. Drawings have still been created that will indicate the cause of the disconnection.

Return to ProCAD Index