MISC-DEFINITIONS Section |
|
|
|
|
This FDF section is for facilities that do not warrant their own separate section. Currently, it is only used to define BEND RADIUS values.
The input structure in this FDF section is a section heading:
MISC-DEFINITIONS
followed by the Bend radius definition:
BEND-RADIUS data units
where
data = the pipe bend radius.
units = Inch or mm, when radius is a value, and D when the radius is a number of pipe diameters.
E.g.
MISC-DEFINITIONS
BEND-RADIUS 5 D
Other typical data inputs are:
BEND-RADIUS 3 D
BEND-RADIUS 5.5 D
BEND-RADIUS 12 INCH
BEND-RADIUS 18.5 INCH
BEND-RADIUS 220 MM
BEND-RADIUS 1250 MM
|
Note. Bend radius information is used by both the C of G and Weights facilities. |