Please note that these lines are alternatives to using Data Arrays for specifying their information.
If Macro 252 - Spindle Control is present this method will be used for
spindle and gear definitions. This is implemented for Advanced Turning.
MS=1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17
|
Position |
Information |
Values |
|
1 |
Type |
Main, Sub, Driven |
|
2 |
ID |
0,1,2,3 |
|
3 |
TurretId |
Value (-1=Not Applicable) |
|
4 |
Type |
0 (Tool), 1 (Work) |
|
5 |
Max RPM |
Value |
|
6 |
MaxAngFeed |
Value |
|
7 |
Direction |
0 (CCLW),1 (CLW) |
|
8 |
MirrorOutput |
0,1 |
|
9 |
CSS Capable |
0 (No), 1 (Yes) |
|
10 |
Rotation |
0 (none),1 (A), 2(B), 3 (C) |
|
11 |
Default Location X |
Value |
|
12 |
Default Location Y |
Value |
|
13 |
Default Location Z |
Value |
|
14 |
DefaultTurretID |
0,1 |
|
15 |
HorsePower |
Value |
|
16 |
DatumToChuckFace |
Value |
|
17 |
RapidRate M/Min |
Value |
These parameters provide information on a specific spindle (one line per spindle).
Here is an example MS line:
MS=Main,0,-1,1,7500,280,0,0,1,3,0,0,0, 0,20,130
MG=1,2,3,4,5(,2,3,4,5(,2,3,4,5(,etc.)))
|
Position |
Information |
Values |
|
1 |
Number of gears defined in line |
Value |
|
2 |
Minimum Rev's Per Minute |
Value |
|
3 |
Theoretical Maximum Rev's Per Minute |
Value |
|
4 |
Recommend Maximum Rev's Per Minute |
Value |
|
5 |
M Code |
Value |
|
(2,... |
Start of next gear specification - you repeat 2 to 5 for each gear you want to set up. |
|
These parameters provide information on a set of gears for a spindle (one line per set of gears).
Here is an example MG line:
MG=2,28,5000,5000,41,5001,7500,7500,42