Override Axis Labels and Range Form



Your Ad Here

Access the Override Axis Labels And Range form as follows:

 

Method 1 - This method can be used to specify parameters for displaying a pushover curve before a static nonlinear analysis has been run.

  1. Click the Define menu > Pushover Parameters Sets command to display a submenu of commands:  Force vs Displacement, ATC 40 Capacity Spectrum, FEMA 356 Coefficient Method, FEMA 440 Equivalent Linearization, FEMA 440 Displacement Modification. Select one of the subcommands to display the Define Pushover Parameters for {Parameter} form; the name of the form depends on the command used.

  2. Click the Add New Parameters button, or highlight a previously defined pushover parameter and click the  Add Copy of Parameters or Modify/Show Parameters button, to display the Parameters for Base Shear vs Monitored Displ form, the Parameters for ATC 40 Capacity Spectrum form, the Parameters for FEMA 356 Coefficient Method form, the Parameters for FEMA 440 Equivalent Linearization form, or the  Parameters for FEMA 440 Displacement Modification form, depending on the command selected in Step 1.

  3. Click the Set Axis Data button to display the Override Axis Labels And Range form.

Method 2 - Use this method to display a pushover curve after an analysis has been run.

  1. Define a static, nonlinear analysis case whose Load Application type is Displacement Control and whose Results Saved type is Multiple States; run a pushover analysis.

  2. Click the Display menu > Show Static Pushover Curve command to display the Pushover Curve form.

  3. Choose the Static Nonlinear Case and Plot Type; click the Add New Parameters, Add Copy of Parameters, or Modify/Show Parameters button to display the Parameters for Base Shear vs Monitored Displ form, the Parameters for ATC 40 Capacity Spectrum form, the Parameters for FEMA 356 Coefficient Method form, the Parameters for FEMA 440 Equivalent Linearization form, or the  Parameters for FEMA 440 Displacement Modification form, depending on the Plot Type selected.

  4. Click the Set Axis Data button to display the Override Axis Labels And Range form.

Method 3 - Use this method to save the parameters specified for displaying a pushover curve as a Named Set for reuse in the future.

  1. Define a static, nonlinear analysis case whose Load Application type is Displacement Control and whose Results Saved type is Multiple States; run a pushover analysis.

  1. Click the Define menu > Named Sets > Pushover Named Sets command to display the Define Pushover Named Sets form.

  2. Click the Add New Named Set button, or highlight a previously defined named set and click the Add Copy of Named Set or Modify/Show Named Set button, to display the Pushover Named Set Data form.

  3. Choose the type of plot to be displayed using the Plot Type drop-down list, choose the Static Nonlinear Case, specify the Plot Parameters, and then click the Add New Parameters, Add Copy of Parameters or Modify/Show Parameters button to display the Parameters for Base Shear vs Monitored Displ form, the Parameters for ATC 40 Capacity Spectrum form, the Parameters for FEMA 356 Coefficient Method form, the Parameters for FEMA 440 Equivalent Linearization form, or the  Parameters for FEMA 440 Displacement Modification form, depending on the Plot Type selected.

  4. Click the Set Axis Data button to display the Override Axis Labels And Range form.

 

Use the Override Axis Labels And Range form to change the labels and ranges used on pushover curves.

 

Return to SAP2000 Index