14.34. LINK34 - Convection Link

www.kxcad.net Home > CAE Index > ANSYS Index > Release 11.0 Documentation for ANSYS


Your Ad Here

Matrix or VectorShape FunctionsIntegration Points
Conductivity Matrix and Heat Generation Load VectorNone (nodes may be coincident)None

14.34.1. Conductivity Matrix

The element conductivity (convection) matrix is

(14–257)

where:

A = area over which element acts (input as AREA on R command)

The effective film coefficient is:

(14–258)

where:

Cc = user input constant (input as CC on R command)

The partial film coefficient term is:

(14–259)

where:

TB = bulk temperature (input as TBULK on SFE command)
H(x) = alternate film coefficient (input on MP,HF command for material x)
me = material number for this element (input on MAT command)
ΔTp = Tp,J - Tp,I
Tp,J = temperature from previous iteration at node J
n = exponent on temperature change (input as EN on R command)

ΔTp must be thought of as unitless, even though it is obviously derived from temperatures.

The heat generation load vector is:

(14–260)

where:

L = distance between nodes

14.34.2. Output

The output is computed as:

(14–261)

where:

Q = heat rate (output as HEAT RATE)
TI = temperature at node I
TJ = temperature at node J

Your Ad Here