www.kxcad.net Home > CAE Index > ANSYS Index > Release 11.0 Documentation for ANSYS


Your Ad Here

PMOPTS, TOLER

Defines percentage tolerance for a p-Method solution.

MP ME ST PR PRN <> <> FL EM <> <> PP <>

TOLER

Percentage tolerance used to determine which elements to fix at the current p-level. If an element's strain energy error is less than this tolerance its p-level will be fixed at the current level. Defaults to 5.

Command Default

Tolerance of 5% will be used.

Notes

Defines the p-level tolerance for p-method solutions (TOLER). The default value is satisfactory for most solutions.

This command is also valid in PREP7.

Distributed ANSYS Restriction. This command is not supported in Distributed ANSYS.

Menu Paths

Main Menu>Preprocessor>Loads>Load Step Opts>p-Method>Solution Options
Main Menu>Solution>Load Step Opts>p-Method>Solution Options