RLOAD1



Your Ad Here

Bulk Data Entry

RLOAD1 – Frequency Response Dynamic Load, Form1

Description

Defines a frequency-dependent dynamic load of the form image\rload1new.gif for use in frequency response problems.

Formula

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RLOAD1

SID

EXCITEID

DELAY

DPHASE

TC

TD

TYPE

 

 

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

RLOAD1

5

3

 

 

1

 

 

 

 

 

Field

Contents

SID

Set Identification number.

No default (Integer > 0)

EXCITEID

Identification number of the DAREA or SPCD entry set that defines A.

No default (Integer > 0)

DELAY

Identification number of the DELAY entry set that defines image\tau.gif.

Default = 0 (Integer > 0)

DPHASE

Identification number of the DPHASE entry set that defines image\lowertheta.gif.

Default = 0 (Integer > 0)

TC

Set identification number of the TABLED1, TABLED2, TABLED3 or TABLED4 entry that gives C(image\hs.gif). See comment 2 below.

Default = 0 if TD is non-zero (Integer > 0)

TD

Set identification number of the TABLED1, TABLED2, TABLED3 or TABLED4 entry that gives D(image\hs.gif). See comment 2 below.

Default = 0 if TC is non-zero (Integer > 0)

TYPE

Identifies the type of the dynamic excitation.

Default = 0 (see comment 5)

Comments

  1. Dynamic load sets must be selected in the I/O Options or Subcase Information sections with the command DLOAD = SID.

  2. If any DELAY, DPHASE, TC, or TD fields are blank or zero, the corresponding image\tau.gif, image\lowertheta.gif, C(image\hs.gif), or D(image\hs.gif) will be zero. Either TC or TD may be blank or zero, but not both.

  3. RLOAD1 loads may be combined with RLOAD2 loads only by specification on a DLOAD entry. This means that the SID on a RLOAD1 entry must not be the same as that on a RLOAD2 entry.

  4. SID must be unique for all RLOAD1 and RLOAD2 entries.

  5. The type field identifies the type of dynamic excitation. Valid entries for this field are listed alongside a description of the dynamic excitation with they invoke.

TYPE

Description

0, L, LO, LOA, LOAD

Applied load; EXCITEID references DAREA data.

1, D, DI, DIS, DISP

Enforced displacement; EXCITEID references SPCD data.

2, V, VE, VEL, VELO

Enforced velocity; EXCITEID references SPCD data.

3, A, AC, ACC, ACCE

Enforced acceleration; EXCITEID references SPCD data.

  1. When EXCITEID refers to an SPCD entry, the modal space will be augmented with displacement vector(s) from linear static analysis with unit prescribed displacement at each of the SPCD degrees of freedom.

Go To

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File

Return to Altair HyperWorks Index