PTUBE



Your Ad Here

Bulk Data Entry

PTUBE – Tube Property

Description

Defines the properties of a thin-walled cylindrical tube element. Referenced by the CTUBE entry.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PTUBE

PID

MID

OD

T

NSM

OD2

 

 

 

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

PTUBE

2

6

6.29

0.25

 

 

 

 

 

 

Field

Contents

PID

Unique identification number.

(Integer > 0)

MID

Material identification number.

(Integer > 0)

OD

Outside diameter of tube.

(Real > 0.0)

T

Thickness of tube.

(Real; T < ½ OD)

NSM

Nonstructural mass per unit length.

(Real)

OD2

Diameter of tube at second grid point – G2 on CTUBE entry. See comment 4.

Default = OD (OD or blank)

Comments

  1. If T is zero, a solid circular rod is assumed.

  2. PTUBE entries must all have unique property identification numbers.

  3. For structural problems, PTUBE entries may only reference MAT1 material entries.

  4. Tapered tubes are not allowed.

  5. PTUBE data is converted to PROD data as it is read into OptiStruct. CTUBE data is converted to CROD data.

Go To

Bulk Data Section

Guidelines for Bulk Data Entries

Alphabetical List of Bulk Data Entries

The Input File