FREQ1



Your Ad Here

Bulk Data Entry

FREQ1 – Frequency List, Alternate Form 1

Description

Defines a set of frequencies to be used in the solution of frequency response problems by specification of a starting frequency, frequency increment, and the number of increments desired.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

FREQ1

SID

F1

DF

NDF

 

 

 

 

 

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

FREQ1

6

2.9

0.5

13

 

 

 

 

 

 

Field

Contents

SID

Identification number.

No default (Integer > 0)

F1

First frequency in set.

No default (Real > 0)

DF

Frequency increment.

No default (Real > 0.0)

NDF

Number of frequency increments.

Default = 1 (Integer > 0)

Comments

  1. FREQ1 entries must be selected with the I/O Options or Subcase Information command FREQUENCY = SID.

  2. The units for F1 and DF are cycles per unit time.

  3. The frequencies defined by this entry are given by image\fiequals.gif
    where i = 1 to (NDF + 1).

  4. All FREQi entries with the same set identification numbers will be used. Duplicate frequencies will be ignored. image\f_sub_n.gif and image\f_sub_n1.gif are considered duplicated if
    image\freq_eq.gif
    where DFREQ is a user parameter with a default of image\10_neg_5.gif , and image\fmin.gif are the maximum and minimum excitation frequencies of the combined FREQi entries.