DTPL



Your Ad Here

Bulk Data Entry

DTPL – Design Variable for Topology Optimization

Description

Defines parameters for the generation of topology design variables.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DTPL

ID

PTYPE

PID1

PID2

PID3

PID4

PID5

PID6

 

 

 

PID7

 

 

 

 

 

 

 

 

 

Optional continuation lines for minimum thickness definition:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

TMIN

T0

 

 

 

 

 

 

 

Optional continuation lines for stress constraint definition:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

STRESS

UBOUND

 

 

 

 

 

 

 

Optional continuation lines for member size constraint definition:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

MEMBSIZ

MINDIM

MAXDIM

 

 

 

 

 

 

Optional continuation lines for mesh type definition:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

MESH

MTYP

 

 

 

 

 

 

 

Optional continuation lines for draw direction constraint definition:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

DRAW

DTYP

DAID/XDA

YDA

ZDA

DFID/XDF

YDF

ZDF

 

 

OBST

OPID1

OPID2

OPID3

OPID4

OPID5

OPID6

OPID7

 

 

 

OPID8

 

 

 

 

 

 

 

 

 

Optional continuation lines for extrusion constraint definition:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

EXTR

ETYP

 

 

 

 

 

 

 

 

EPATH1

EP1_ID1

EP1_ID2

EP1_ID3

EP1_ID4

EP1_ID5

EP1_ID6

EP1_ID7

 

 

 

EP1_ID8

 

 

 

 

 

 

 

 

 

 

EPATH2

EP2_ID1

EP2_ID2

EP2_ID3

EP2_ID4

EP2_ID5

EP2_ID6

EP2_ID7

 

 

 

EP2_ID8

 

 

 

 

 

 

 

 

 

Optional continuation lines for "Master" definition for pattern repetition constraint:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

MASTER

 

 

 

 

 

 

 

 

 

COORD

CID

CAID/XCA

YCA

ZCA

CFID/XCF

YCF

ZCF

 

 

 

 

CSID/XCS

YCS

ZCS

CTID/XCT

YCT

ZCT

 

Optional continuation lines for "Slave" definition for pattern repetition constraint:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

SLAVE

DTPL_ID

SX

SY

SZ

 

 

 

 

 

COORD

CID

CAID/XCA

YCA

ZCA

CFID/XCF

YCF

ZCF

 

 

 

 

CSID/XCS

YCS

ZCS

CTID/XCT

YCT

ZCT

 

Optional continuation lines for pattern grouping constraint definition:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

PATRN

TYP

AID/XA

YA

ZA

FID/XF

YF

ZF

 

 

 

UCYC

SID/XS

YS

ZS

 

 

 

 

Optional continuation lines for material definition if PTYPE=COMP:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

 

MAT

MATOPT

 

 

 

 

 

 

 

Example 1

Define a topology design variable that allows the thickness of components referencing the PSHELL properties 7, 8, and 17 to vary between 1.0 and 5.0 (the thickness defined on PSHELL definitions with PID 7, 8, and 17 is 5.0). The optimized design should contain members whose width is no less than 60.0 units.

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DTPL

1

PSHELL

7

8

17

 

 

 

 

 

MEMBSIZ

60.0

 

 

 

 

 

 

 

 

TMIN

1.0

 

 

 

 

 

 

 

Example 2

Define a topology design variable for components referencing the PSOLID properties 4, 5, and 6. The optimized design should contain members whose diameter is no less than 60.0 units. The final design will be manufactured using a casting process, where the draw direction lies along the x-axis. The components referencing PSOLID properties 10, 11, and 12 are non-designable, but will form part of the same casting as the designable components.

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DTPL

1

PSOLID

4

5

6

 

 

 

 

 

MEMBSIZ

60.0

 

 

 

 

 

 

 

 

DRAW

SPLIT

0.0

0.0

0.0

1.0

0.0

0.0

 

 

OBST

10

11

12

 

 

 

 

 

 

Field

Contents

ID

Each DTPL card must have a unique ID.

No default (integer > 0)

PTYPE

Property type for which DTPL card is defined, PCOMP, PBAR, PBUSH, PROD, PSHELL, PSOLID, or PWELD.

No default (PCOMP, PBAR, PBUSH, PROD, PSHELL, PSOLID, or PWELD)

PID#

Property identification numbers. List of properties of type PTYPE for which this DTPL card is defined. Use ALL in PID1 field, if it applies to all properties of type PTYPE in the model.

If no PIDs are listed, OptiStruct will check all properties of type PTYPE to see if they are to be included in the design space (see help section for PCOMP, PSHELL, and PSOLID). If any properties satisfy this search, then they will be affected by entries on this card. In this situation (where no PIDs are defined), only one DTPL card can be defined for the given PTYPE.

Default = blank (integer > 0, blank or ALL)

TMIN

TMIN flag indicating that minimum thickness value will follow. Only valid when PTYPE = PSHELL.

If not present when PTYPE = PSHELL, then minimum thickness will default to the T0 value defined on the PSHELL card. If no T0 value is defined on the PSHELL card, the minimum thickness will default to 0.0.

T0

Minimum thickness for PSHELL properties when the referenced material is of type MAT1.

If PSHELL references a material which is not of type MAT1, this value is ignored and T0 = 0.0 is used.

If no value is entered for T0, the T0 value on the PSHELL card is used. If T0 is not defined on the PSHELL card, then T0=0.0 is assumed.

Default = blank (Real > 0.0)

STRESS

STRESS flag indicating that stress constraints are active and that an upper bound value for stress is to follow. See comment 1 below.

UBOUND

Upper bound constraint on stress.

No default (real > 0.0)

MEMBSIZ

MEMBSIZ flag indicating that member size control is active for the properties listed. Indicates that MINDIM and possibly MAXDIM are to follow.

MINDIM

Specifies the minimum diameter of members formed. This command is used to eliminate small members. It also eliminates checkerboard results. See comment 2 below.

Default = No Minimum Member Size Control (real > 0.0)

MAXDIM

Specifies the maximum diameter of members formed. This command is used to prevent the formation of large members. It can only be used in combination with MINDIM. See comment 3 below.

Default = No Maximum Member Size Control (real > 0.0)

MESH

MESH flag indicating that mesh type information is to follow.

MTYP

Indicates that the mesh conforms to certain rules for which the optimizer is tuned. Currently, only the ALIGN option is available. ALIGN indicates that when manufacturing constraints are active, the mesh is aligned with the draw direction or extrusion path. See comment 4.

Default = blank (ALIGN or blank)

DRAW

DRAW flag indicating that casting constraints are being applied. Indicates that draw direction information is to follow.

Only valid for PTYPE = PSOLID. OptiStruct will terminate with an error if present for other PTYPEs.

DTYP

Type of draw direction constraint to be used. Can choose between SINGLE, SPLIT, SPLIT2, or SPLIT3. SINGLE indicates that a single die will be used, the die being withdrawn in the given draw direction. SPLIT allows the optimization of the splitting surface of two dies, with both dies moving apart in the given draw direction. SPLIT2 and SPLIT3 provide alternative methods to optimize the splitting surface. These should only be used in the case where SPLIT creates non-castable cavities.

Default = SPLIT (SINGLE, SPLIT, SPLIT2, SPLIT3)

DAID/XDA, YDA, ZDA

Draw direction anchor point. These fields define the anchor point for draw direction of the casting. The point may be defined by entering a grid ID in the DAID field or by entering X, Y, and Z coordinates in the XDA, YDA, and ZDA fields, these coordinates will be in the basic coordinate system.

Default = origin (Real in all three fields or integer in first field)

DFID/XDF, YDF, ZDF

Direction of vector for draw direction definition. These fields define a point. The vector goes from the anchor point to this point. The point may be defined by entering a grid ID in the DFID field or by entering X, Y, and Z coordinates in the XDF, YDF, and ZDF fields, these coordinates will be in the basic coordinate system.

No default (Real in all three fields or integer in first field)

OBST

OBST flag indicating that a list of PIDs will follow which are non-designable, but their interaction with designable parts needs to be considered with regard to the defined draw direction. OBST stands for obstacle.

Only recognized if DRAW flag is also present on same DTPL card. OptiStruct will terminate with an error if OBST flag is present without DRAW flag.

OPID#

Obstacle property identification number. List of non-designable properties that are to be considered with regard to the defined draw direction. These must be PSOLID.

No default (integer > 0, blank or ALL)

EXTR

EXTR flag indicating that extrusion constraints are being applied. Indicates that extrusion information is to follow.

Only valid for PTYPE = PSOLID. OptiStruct will terminate with an error if present for other PTYPEs.

ETYP

Type of extrusion constraint to be used. Can choose between NOTWIST or TWIST. NOTWIST indicates that the cross section cannot twist about the neutral axis, in which case only one path needs to be defined. TWIST indicates that the cross section can twist about the neutral axis, in which case two paths need to be defined.

Default = NOTWIST (NOTWIST or TWIST)

EPATH1

EPATH1 flag indicating that a list of grid IDs will follow to define the primary extrusion path.

Only recognized if EXTR flag is also present on same DTPL card. OptiStruct will terminate with an error if EPATH1 flag is present without EXTR flag.

EP1_ID#

Primary extrusion path identification numbers. List of grid IDs that define the primary extrusion path.

No default (integer > 0 or blank)

EPATH2

EPATH2 flag indicating that a list of grid IDs will follow to define the secondary extrusion path. This is only required when ETYP has been set to TWIST.

Only recognized if EXTR flag is also present on same DTPL card. OptiStruct will terminate with an error if EPATH2 flag is present without EXTR flag.

EP2_ID#

Secondary extrusion path identification numbers. List of grid IDs that define the secondary extrusion path.

No default (integer > 0 or blank)

MASTER

MASTER flag indicating that this design variable may be used as a master pattern for pattern repetition. See comment 6 below.

COORD

COORD flag indicating information regarding the coordinate system for pattern repetition is to follow. This is required if either MASTER or SLAVE flags are present.

CID

Coordinate system ID for a rectangular coordinate system that may be used as the pattern repetition coordinate system. See comment 6 below.

Default = 0 (Integer > 0)

CAID/XCA, YCA, ZCA

Anchor point for pattern repetition coordinate system. The point may be defined by entering a grid ID in the CAID field or by entering X, Y, and Z coordinates in the XCA, YCA, and ZCA fields. These coordinates will be in the basic coordinate system. See comment 6 below.

No Default (Real in all three fields or integer in first field)

CFID/XCF, YCF, ZCF

First point for pattern repetition coordinate system. The point may be defined by entering a grid ID in the CFID field or by entering X, Y, and Z coordinates in the XCF, YCF, and ZCF fields. These coordinates will be in the basic coordinate system. See comment 6 below.

No default (Real in all three fields or integer in first field)

CSID/XCS, YCS, ZCS

Second point for pattern repetition coordinate system. The point may be defined by entering a grid ID in the CSID field or by entering X, Y, and Z coordinates in the XCS, YCS, and ZCS fields. These coordinates will be in the basic coordinate system. See comment 6 below.

No default (Real in all three fields or integer in first field)

CTID/XCT, YCT, ZCT

Third point for pattern repetition coordinate system. The point may be defined by entering a grid ID in the CTID field or by entering X, Y, and Z coordinates in the XCT, YCT, and ZCT fields. These coordinates will be in the basic coordinate system. See comment 6 below.

No default (Real in all three fields or integer in first field)

SLAVE

SLAVE flag indicating that this design variable is slaved to the master pattern definition referenced by the following DTPL_ID entry. See comment 6 below.

DTPL_ID

DTPL identification number for a master pattern definition.

No default (integer > 0)

SX, SY, SZ

Scale factors for pattern repetition in X, Y, and Z directions respectively. See comment 6 below.

Default = 1.0 (Real > 0.0)

PATRN

PATRN flag indicating that pattern grouping is active for the properties listed. Indicates that information for pattern grouping is to follow.

Only valid for PTYPE = PCOMP, PSHELL, and PSOLID. OptiStruct will terminate with an error if present for other PTYPEs.

TYP

Indicates the type of pattern grouping requested. See comment 9 below.

Default = No Pattern Grouping (1, 2, 3, 9, 10, or 11)

AID/XA, YA, ZA

Anchor point for pattern grouping. The point may be defined by entering a grid ID in the AID field or by entering X, Y, and Z coordinates in the XA, YA, and ZA fields. These coordinates will be in the basic coordinate system. See comment 9 below.

Default = origin (Real in all three fields or integer in first field)

FID/XF, YF, ZF

First point for pattern grouping. The point may be defined by entering a grid ID in the FID field or by entering X, Y, and Z coordinates in the XF, YF, and ZF fields. These coordinates will be in the basic coordinate system. See comment 9 below.

No default (Real in all three fields or integer in first field)

UCYC

Number of cyclical repetitions for cyclical symmetry. This field defines the number of radial "wedges" for cyclical symmetry. The angle of each wedge is computed as 360.0 / UCYC. See comment 9 below.

Default = blank (Integer > 0 or blank)

SID/XS, YS, ZS

Second point for pattern grouping. The point may be defined by entering a grid ID in the SID field or by entering X, Y, and Z coordinates in the XS, YS, and ZS fields. These coordinates will be in the basic coordinate system. See comment 9 below.

No default (Real in all three fields or integer in first field)

MAT

Indicates the type of composite topology optimization. Only considered for PTYPE=PCOMP.

MATOPT

PLY: Indicates that the optimization should be performed at the ply level. Topology design variables are applied to each ply individually. This method allows the optimization process to determine which orientation is preferred for each element.

HOMO: Indicates that the optimization should be performed on the homogenized shell. This is the method which was used in previous versions of OptiStruct.

Default = PLY

Comments

1.        Von Mises stress constraints may be defined for topology and free-size optimization through the STRESS optional continuation line on the DTPL or the DSIZE card. There are a number of restrictions with this constraint:

·      The definition of stress constraints is limited to a single von Mises permissible stress. The phenomenon of singular topology is pronounced when different materials with different permissible stresses exist in a structure. Singular topology refers to the problem associated with the conditional nature of stress constraints, i.e. the stress constraint of an element disappears when the element vanishes. This creates another problem in that a huge number of reduced problems exist with solutions that cannot usually be found by a gradient-based optimizer in the full design space.

·      Stress constraints for a partial domain of the structure are not allowed because they often create an ill-posed optimization problem since elimination of the partial domain would remove all stress constraints. Consequently, the stress constraint applies to the entire model when active, including both design and non-design regions, and stress constraint settings must be identical for all DSIZE and DTPL cards.

·      The capability has built-in intelligence to filter out artificial stress concentrations around point loads and point boundary conditions. Stress concentrations due to boundary geometry are also filtered to some extent as they can be improved more effectively with local shape optimization.

·      Due to the large number of elements with active stress constraints, no element stress report is given in the table of retained constraints in the .out file. The iterative history of the stress state of the model can be viewed in HyperView or HyperMesh.

·      Stress constraints do not apply to 1-D elements.

·      Stress constraints may not be used when enforced displacements are present in the model.  

2.        It is recommended that a MINDIM value be chosen which allows for the formation of members that are at least 3 elements thick. When pattern grouping, draw direction, or extrusion constraints are active, a MINDIM value of 3 times the average element edge length is enforced, and user-defined values (which are smaller than this value) will be replaced by this value.

If MINDIM is defined, but no other manufacturing constraint exists, MINDIM will not be set to the recommended value for PTYPE = PSHELL or PSOLID. For PTYPE = PCOMP, MINDIM will also be reset in the absence of manufacturing constraints.

3.        MAXDIM should at least be twice the value of MINDIM, and OptiStruct will terminate with an error if a MAXDIM of less than 6 times the average element edge length is defined.

The MAXDIM constraint introduces significant restriction to the design problem. Therefore, it should only be used when it is a necessary design requirement. A study without MAXDIM should always be carried out in order to compare the impact of this additional constraint.

4.        MTYP "ALIGN" may be used in conjunction with draw direction or extrusion manufacturing constraints to indicate that a mesh is aligned with a draw direction or extrusion path.

image\dtpl_comment_9.gif

Mesh 1 is "aligned" for draw direction 1 in the example shown, but not for draw direction 2.

MTYP "ALIGN" may also be used in conjunction with manufacturing constraints (minimum member, maximum member, pattern grouping, and pattern repetition) other than draw direction and extrusion, and Mesh 1 is considered "aligned" for those manufacturing constraints, too.

In both cases, this will enable OptiStruct to use a smaller minimum member size and smaller maximum member sizes. The default minimum member size is three times the average element edge length; with an "aligned" mesh, the default size can be two times the average element edge length.

Mesh 2 in the example shown is not "aligned" in any case.

5.        Extrusion constraints cannot be combined with draw direction constraints.

6.        Pattern repetition allows similar regions of the design domain to be linked together so as to produce similar topological layouts. This is facilitated through the definition of "Master" and "Slave" regions. A DTPL card may only contain one MASTER or SLAVE flag. For both "Master" and "Slave" regions, a pattern repetition coordinate system is required and is described following the COORD flag. In order to facilitate reflection, the coordinate system may be a left-handed or right-handed Cartesian system. The coordinate system may be defined in one of two ways, listed here in order of precedence:

·      Four points are defined and these are utilized as follows to define the coordinate system (this is the only way to define a left-handed system):

-   A vector from the anchor point to the first point defines the x-axis.

-   The second point lies on the x-y plane, indicating the positive sense of the y-axis.

-     The third point indicates the positive sense of the z-axis.

·      A rectangular coordinate system and an anchor point are defined. If only an anchor point is defined, it is assumed that the basic coordinate system is to be used.

Multiple "Slaves" may reference the same "Master."

Scale factors may be defined for "Slave" regions, allowing the "Master" layout to be adjusted.

For a more detailed description, please refer to the Pattern Repetition page contained within the User's Guide section Manufacturability for Topology Optimization.

7.        Pattern grouping is applicable for PCOMP, PSHELL, and PSOLID components only.

8.        For historic reasons, the SYMM flag may be used in place of the PATRN flag.

9.        Currently there are six pattern grouping options:

1-plane symmetry (TYP = 1)

This type of pattern grouping requires the anchor point and first point to be defined. A vector from the anchor point to the first point is normal to the plane of symmetry.

2-plane symmetry (TYP = 2)

This type of pattern grouping requires the anchor point, first point, and second point to be defined. A vector from the anchor point to the first point is normal to the first plane of symmetry. The second point is projected normally onto the first plane of symmetry. A vector from the anchor point to this projected point is normal to the second plane of symmetry.

3-plane symmetry (TYP = 3)

This type of pattern grouping requires the anchor point, first point, and second point to be defined. A vector from the anchor point to the first point is normal to the first plane of symmetry. The second point is projected normally onto the first plane of symmetry. A vector from the anchor point to this projected point is normal to the second plane of symmetry. The third plane of symmetry is orthogonal to both the first and second planes of symmetry, passing through the anchor point.

Uniform (TYP = 9)

This type of pattern grouping does not require any additional input.

Cyclic (TYP = 10)

This type of pattern grouping requires the anchor point, first point, and number of cyclical repetitions to be defined. A vector from the anchor point to the first point defines the axis of symmetry.

Cyclic with symmetry (TYP = 11)

This type of pattern grouping requires the anchor point, first point, second point, and number of cyclical repetitions to be defined. A vector from the anchor point to the first point defines the axis of symmetry. The anchor point, first point, and second point all lay on a plane of symmetry. A plane of symmetry lies at the center of each cyclical repetition.

For a more detailed description, please refer to the Pattern Grouping page contained within the User's Guide section Manufacturability for Topology Optimization.

Go To

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File

See Also

Topology Optimization

Return to Altair HyperWorks Index