CVISC



Your Ad Here

Bulk Data Entry

CVISC – Viscous Damper Connection

Description

Defines a viscous damper element.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CVISC

EID

PID

G1

G2

 

 

 

 

 

Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CVISC

2

64

12

63

 

 

 

 

 

 

Field

Contents

EID

Unique element identification number.

No default (Integer > 0)

PID

Identification number of a PVISC entry.

Default = EID (Integer > 0)

G1, G2

Geometric grid point identification numbers of connection points.

No default (integer > 0)

Comments

  1. G1 image\notequal.gif G2.

  2. Element identification numbers must be unique with respect to all other element identification numbers.

  3. Only one viscous damper element may be defined on a single entry.

Go To

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File

Return to Altair HyperWorks Index