Modeling > Modeling Flow and Energy > Flow Reference > Conditions > Non-Reflecting Option

Your Ad Here




Non-Reflecting Option

This is a boundary condition on stagnation inlet and pressure outlet boundaries. It is only available when the Coupled Flow model, Ideal Gas model, Steady model, and Two-Dimensional or Three-Dimensional model are enabled. It is only appropriate to use this option on boundaries of linearly (two-dimensional) or rotationally (three-dimensional) periodic problems in which the flow normal to the non-reflecting boundary remains subsonic. In three-dimensional simulations the boundary must be a surface of revolution. Furthermore, the boundary mesh must be a structured, mapped mesh of quadrilateral faces. In the event these conditions are not satisfied an error will be generated during pre-processing of the boundary mesh prior to application of the non-reflecting boundary condition procedure.

Properties

Non-Reflecting Option

Specifies whether or not to use the non-reflecting option.

 

Ticked

Use the non-reflecting option.

 

Cleared

Do not use the non-reflecting option.

Note:

No additional nodes appear in the Values node when this option is ticked. However, there are some restrictions as to which methods are appropriate for specifying other boundary values. The table below indicates which methods can be used with which boundary values when this option is ticked.

 

Method

Boundary Value

Constant

Radial
Equilib.

Tabular
Data

Field
Function

Total pressure

Yes

No

3D1

No

Static pressure

Yes

Yes2

3D1

No

Total temperature

Yes

No

3D1

No

Flow direction

Yes

No

3D1

No

Notes:

1 External radial tabular data files only, not internal or xyz formatted.
2 At a pressure outflow boundary only.

All existing Methods for turbulence quantities and other transported scalars are acceptable.