www.kxcad.net Home > CAE Index > MSC Software Index > Adams MD R2 Index
Identifies the new result set component. Identifies two result set components on which to perform the operation. No_units, Calculate, Length, Angle, Mass, Density, Time, Area, Volume, Velocity, Acceleration, Angular_velocity, Angular_acceleration, Inertia, Area_inertia, Damping, Stiffness, Torsion_stiffness, Torsion_damping, Force, Torque, Pressure, Force_time, Torque_time Specifies the type of units to be used for the new result set component. Once you set the unit type, Adams/View can perform the proper unit conversion on the data.
1.
• In an existing result set, the name must include the result set. For example, assume you have a request file called SHIFT.REQ, and it contains the result set REQ1. If you want to store the new result set component in result set REQ1 with the component name NEW, enter:
• In a new results set, named REQ99, for example, in the analysis run SHIFT, enter .SHIFT.REQ99.NEW. The number of components to be stored is inferred by the number of components named in this parameter. You can enter multiple names separated with commas (,).The component name must be unique, even though it can be stored in an existing result set. A result set name can be of any length and any combination of alphanumeric characters. The leading character must be a letter.Result sets are associated with an analysis and can be identified as such. A result set associated with request 101 from an analysis named test is often referred to as .test.req101.The table below illustrates the default names assigned to result sets and result set components, read from request (.req) and results (.res) files.
Result set name File that result is from
2. If the value for the “units” parameter is calculate, Adams/View tries to determine the units to use for this operation. For example, if velocities are added (length/time), then the calculated “units” parameter for the new result set component is velocity (length/time). If the derivative of a velocity is taken, the calculated “units” parameter is acceleration (length/time**2).Adams/View can only handle calculated units with a maximum exponent for the base units (force, length, mass, time) of plus or minus four. For example, if a result set component with the units (length/time**3) is multiplied with a result set component having the same units, it gives the calculated units (length**2/time**6). Because the exponent of time is greater than four, Adams/View uses no_units and issues a warning.Values are: no_units, calculate, length, angle, mass, density, time, area, volume, velocity, acceleration, angular_velocity, angular_acceleration, inertia, area_inertia, damping, stiffness, torsion_stiffness, torsion_damping, force, torque, pressure, force_time, torque_time.